| | LGB21/41系列燃氣燃燒器控制器(SIEMENS) | | | ⊙ 產品詳細說明 | | | 產品介紹 | | The LGB... burner controls are used for the startup and supervision of single- or 2-stage gas or gas / oil burners in intermittent operation. Depending on the type of burner control used, the flame is supervised either by an ionization probe, a blue-flame detector QRC1... for forced draft gas / oil burners, or a UV detector QRA... (with auxiliary unit AGQ1...A27). In connection with the respective adapters, the LGB... burner controls replace their predecessor types LFI7... and LFM1... (also refer to ?Replacement types under Ordering). -
Automatic forced draft burners for gaseous fuels to EN 676 -
Gas burner controls to EN 298 -
Undervoltage detection -
Air pressure supervision with functional check of the air pressure monitor during startup and operation -
Electrical remote reset facility -
LGB41... for use with atmospheric gas burners | | 型號表 | | 型號 | 認證 | tw/s | t1/s | TSA/s | t3n/s | t3/s | t4/s | t9/s | t10/s | t11/s | t12/s | t20/s | | LGB21.130A27 | CH,EU,S,SF | 8 | 7 | 3 | 2.4 | 2 | 8 | - | 5 | - | - | 6 | | LGB21.230A27 | CH,EU,S,SF | 8 | 15 | 3 | 2.4 | 2 | 8 | - | 5 | - | - | 38 | | LGB21.330A27 | CH,EU,H,S,SF | 8 | 30 | 3 | 2.4 | 2 | 8 | - | 5 | - | - | 23 | | LGB21.350A27 | CH,EU,H,S,SF | 8 | 30 | 5 | 4 | 2 | 10 | - | 5 | - | - | 2 | | LGB21.550A27 | AUS,DH,EU | 8 | 50 | 5 | 4 | 2 | 10 | - | 5 | - | - | 2 | | LGB22.130A27 | CH,EU,N,S | 9 | 7 | 3 | 2.4 | 3 | 8 | - | 3 | 12 | 12 | 21 | | LGB22.230B27 | CH,EU,N,S,SF | 9 | 20 | 3 | 2.4 | 3 | 8 | - | 3 | 16.5 | 16.5 | 2 | | LGB22.330A27 | AUS,CH,EU,H,N,S,SF | 9 | 30 | 3 | 2.4 | 3 | 8 | - | 3 | 12 | 11 | 2 | | LGB22.330A270 | EU | 9 | 30 | 3 | 2.4 | 3 | 8 | - | 3 | 12 | 11 | 2 | | LGB32.130A27 | CH,EU | 9 | 7 | 3 | 2.4 | 3 | 8 | - | 3 | 12 | 12 | 21 | | LGB32.230A27 | CH,EU | 9 | 20 | 3 | 2.4 | 3 | 8 | - | 3 | 16.5 | 16.5 | 2 | | LGB32.330A27 | CH,EU | 9 | 30 | 3 | 2.4 | 3 | 8 | - | 3 | 12 | 11 | 2 | | LGB32.350A27 | CH,EU | 9 | 30 | 5 | 4.4 | 1 | 10 | - | 3 | 12 | 9 | 2 | | LGB41.255A27 | EU | 18 | - | 5 | 4 | 2 | 10 | 5 | - | - | - | 10 | | LGB41.258A27 | CH,EU,H,SF | 18 | - | 5 | 4 | 2 | 10 | 9 | - | - | - | 10 | | | tw | 等待時間 | | t1 | 預吹掃時間 | | TSA | 點火安全時間 | | t3 | 預點火時間 | | t3n | 后點火時間 | | t4 | 電磁閥1到電磁閥2的間隔時間,或電磁閥1到比例控制開始的間隔時間 | | t9 | 第二安全時間(僅LGB41...) | | t10 | 空氣壓力信號建立時間 | | t11 | 伺服馬達程序打開時間 | | t12 | 伺服馬達程序關閉時間 | | t20 | 自鎖定后的程序內部循環(huán)時間 | | | | 技術參數 | | 主要參數 | | 主電壓 | AC220V -15%...AC240V +10%(LGB2../LGB4...) | | AC230V -15%/+10%(LGB32...) | | AC100V -15%...AC110V +10% | | 主頻率 | 50...60Hz ±6% | | 外部保險絲 | 10A | | 功率 | 3VA | | 重量 | 230g | | 保護等級 | IP40 | | 額定電流 | | | 端子3 | 3A(可在0.5S內到15A) | | 端子4,5,7 | 2A | | 端子9,10 | 1A | | 端子12 | 5A | | | | | 環(huán)境條件 | | 運輸環(huán)境 | IEC 721-3-2 | | 內部條件 | class 2K2 | | 溫度范圍 | -50...+60ºC | | 機械條件 | class 2M2 | | 濕度 | <95% | | 運行環(huán)境 | IEC 721-3-3 | | 內部條件 | class 3K5 | | 機械條件 | class 3M2 | | 溫度范圍 | -20...+60ºC | | 濕度 | <95% | | 不得進水 | | | | |